5.1.8 RS485 Setup
This menu allows the user to setup the parameters of the unit’s RS-485
communications port. From the System Setup menu, select <RS485 Setup>
and press ENTER. The following menu is displayed.
RS485 Setup
1. Unit ID
2. Baud Rate
3. Bits
4. Stop
5. Parity
224
9600
8
1
None
5.1.8.1 Unit ID
This item is used to change the RS-485 ID address of the DVR. The ID is in
the range of <1> to <255>.
5.1.8.2 Baud Rate
The Baud rate options for associated with the protocol are <2400>, <4800>,
<9600>, <19200>, <38400>, and <57600>..
5.1.8.3 Bits
Users can specify the bits in a word associated with this protocol. The
available options are <6>, <7> and <8> bits.
5.1.8.4 Stop
Users can specify the stop bit associated with this protocol. Options are <1>
and <2> stop bits.
5.1.8.5 Parity
This item is used to specify the parity associated with this protocol. Options
are <ODD>, <EVEN> and <None>.